The LD 450 meets the requirements of class I instruments for the norm “Standard Test Method for Leaks with Ultrasound” (ASTM Int. – E1002-05)
Application: Leak detection on: compressed air, gas and vacuum systems; door seals.
Technical data:
- Operating frequency: 40 kHz ± 2 kHz
- Connections:
- 3.5 mm stereo jack for headset.
- Power supply socket for connecting an external charger
- Laser:
- Wavelength: 630…660 nm
- Output power: < 1 mW (laser class 2)
- Operating time: ˃10 h (Continuous operation)
- Charging time: approx. 1.5 h
- Operating temperature: -5 °C to 50 °C
- Storage temperature: -20 °C to +60 °C